The first decision is the inspection type, A, B or C, which depends on how independent the body is from the items it inspects. That choice shapes the impartiality arrangements for the whole system.
Scope follows: the fields of inspection, the items, the methods and the locations. A gap analysis then compares current practice against the standard, including how inspectors are qualified and authorised, how equipment is controlled and how inspection methods are documented.
Records, reports and certificates are designed so that each conclusion can be traced back to the observation behind it. Complaints and appeals, subcontracting and confidentiality are set up, and an internal audit and management review test the system before assessment.
A common pitfall is relying on the experience of senior inspectors without writing down how they reach decisions. The standard expects methods that a newly authorised inspector could follow and reach the same result, so turning expertise into documented criteria is often the largest single task.