ISO & GRC consulting across India since 2003 Find consultants near you
FILM / ISO 15189

ISO 15189 requirements explained

A short guide to what ISO 15189 requires of a medical laboratory, set out as business areas rather than clause numbers.

FILM LENGTH
2:00
STANDARD
ISO 15189
FORMAT
Requirements explained

Talk to a Lakshy ISO 15189 consultant

Our ISO 15189 expert will get back to you within one business day.

NO SPAM · NO OBLIGATION · CONFIDENTIAL
VIDEO
OVERVIEW

What the video covers

ISO 15189 sets requirements for quality and competence in medical laboratories. It is built for the clinical setting, so patient safety and the needs of the requesting clinician run through every part of it.

This short film walks through the main areas an assessor will look at, in the order a laboratory manager would naturally think about them.

KEY POINTS

The main requirement areas

General and structural requirements cover impartiality, confidentiality, patient-related duties, legal responsibility and a clear organisation with defined authority for the laboratory director.

Resource requirements deal with people, facilities, equipment and its calibration, traceability of measurements to recognised references, reagents, consumables, and any externally provided products or referral laboratories.

Process requirements follow the sample: request and collection, transport and receipt, selection and verification of methods, measurement uncertainty, assuring the validity of results through internal quality control, external quality assessment schemes, reporting, and release of results. Nonconforming work, data control and complaints also sit here.

Management system requirements bring in risk-based thinking, document and record control, corrective action, internal audit and management review.

Two themes run across every area. The first is risk management focused on the patient, so the laboratory must think about what could harm a patient and act before it does. The second is advisory service: the laboratory is expected to help clinicians choose the right test and interpret results, not only to produce numbers.

HOW WE HELP

How Lakshy helps

Lakshy translates each area into the forms, logs and habits a busy laboratory can sustain. Our free ISO 15189 gap analysis tool shows which areas need the most work, and our consultants then help you close the gaps before the NABL assessment.

KEY TAKEAWAYS

What to remember

  • ISO 15189 combines technical competence with patient-focused service.
  • Requirements follow the sample from request to released report.
  • Risk management and impartiality are expected throughout the laboratory.
  • A gap analysis shows where effort is needed before assessment.
INCLUDED IN EVERY LAKSHY ENGAGEMENT

Software and e-learning, at no extra cost

Effivity ISO & GRC software

Run your management system in software, not spreadsheets.

A five-user Effivity subscription comes with every engagement: documents and records, internal audits, corrective actions and KPI dashboards in one place, configured by the expert who builds your system.

See what Effivity includes →
Sterling Academy e-learning

Build awareness across your whole team.

Complimentary awareness e-learning on your standards for your employees, with practice checkpoints, a final exam and a numbered Certificate of Completion, verifiable online. More courses, from practitioner to internal auditor, are available on Sterling Academy.

Visit Sterling Academy →
FAQS

Frequently asked questions

How is ISO 15189 different from ISO/IEC 17025?

Both address competence, but ISO 15189 is written for medical laboratories. It adds requirements on patient safety, sample collection, clinical advice and communication of critical results, which a testing and calibration laboratory working to ISO/IEC 17025 would not normally face.

Who assesses ISO 15189 laboratories in India?

NABL, the National Accreditation Board for Testing and Calibration Laboratories, assesses and accredits medical laboratories against ISO 15189 in India. Lakshy works as a consultant and prepares the laboratory; the accreditation decision rests with NABL.

NEXT STEP

Start with a free ISO 15189 gap assessment.

Thirty minutes with a senior specialist, benchmarking your organisation against every requirement of the standard. No cost. No obligation.

Book My Free Session
BUYER BEWAREA certificate in 7–10 days — no audit, no implementation — is not certification. It is paper.Know the red flags →
Scroll to Top