ISO 22301 Consultants in Noida

ISO 22301 consulting and certification support for organisations in Noida. Typical clients: Data centres and operations selling continuity commitments.

Get Started

ISO consultants in Noida reply within one business day. hello@lakshy.com · +91 98217 80035

NO SPAM · NO OBLIGATION · CONFIDENTIAL
ISO 22301 IN NOIDA

Continuity for Noida’s data centres and round-the-clock operations

Noida and Greater Noida are becoming a data centre location for northern India. Invest UP reported in late 2022 the inauguration of the first building of the Greater Noida Data Center Park, with foundation stones laid for further buildings at the same time.[1] Uttar Pradesh’s Data Center Policy 2026, notified by a government order dated 9 July 2026, sets out to encourage the industry to add 2GW and more of capacity in the state and covers Tier III and IV facilities certified by agencies such as Uptime and TIA.[2] Alongside the data centres sit IT/ITES special economic zones at Sectors 126, 144 and 157 in Noida and in the Greater Noida Techzone, where delivery centres run around the clock for clients elsewhere.[3]

Customers of these facilities buy uptime. Colocation clients, cloud tenants and outsourcing clients write recovery times and availability levels into contracts and audit them. ISO 22301, the international standard for business continuity management systems, gives an operator a structured way to show that those commitments rest on analysis and tested plans: a business impact analysis that sets recovery objectives, a risk assessment of power, cooling, connectivity and people, documented strategies and plans, and exercises whose results drive improvement. Certification by an accredited body gives customers an independent view of that system.

POLICY EXPECTATIONS

What the state’s data centre policy expects

The 2026 policy explicitly lists physical security infrastructure and disaster recovery provisions among eligible infrastructure, and describes its non-disturbance provision as giving data centre parks assured business continuity.[2] It also provides for 24×7 power supply where the park or unit arranges two dedicated feeders.[2] Operators that take up these provisions will be expected by customers to show that dual feeds, generators, fuel contracts and cooling redundancy are tested, maintained and supported by trained staff, not only installed.

ISO 22301 turns those engineering provisions into a managed system. It requires the operator to identify the activities that deliver each service, the resources and suppliers they depend on, and the time within which each must be restored. For a Greater Noida data hall, this means mapping utility feeds, generator fuel supply, chiller plant, network carriers and remote-hands staff, and planning for their loss one at a time and in combination.

Delivery centres face a broader mix of risks. Pollution-related restrictions under the Commission for Air Quality Management’s directions can limit generator use and travel, and the Commission has banned unapproved fuels across the NCR since 1 January 2023.[4] Heavy monsoon rain, extreme heat and transport disruption on the expressways affect staff attendance. A Noida centre’s plan should state how work shifts to remote staff or to another site, and how client approvals for that shift are obtained in time.

Supplier concentration deserves attention in Noida as well. Data centres and delivery centres in the district draw on a limited pool of power utilities, diesel suppliers, chiller maintenance contractors, carriers and staffing agencies. The business impact analysis should show where several critical services rely on the same supplier, and the plan should record what alternative exists, how long it takes to bring in, and who has authority to call it.

RULES THAT APPLY

Obligations that stay in force during a Noida disruption

  • CERT-In directions. Data centres, cloud and VPN providers keep specified subscriber records for five years, every covered entity reports specified incidents within 6 hours, and logs are retained in India for a rolling 180 days.[5] Recovery sites must keep these duties running.
  • DPDP Act and Rules. Personal data breaches must be notified to affected individuals without delay; the Rules were notified on 14 November 2025.[6]
  • Pollution consent. Generator sets and cooling plant are covered by consent and authorisation conditions administered by the Uttar Pradesh Pollution Control Board, whose portal routes applications through Nivesh Mitra.[7]
  • Labour codes. Extended shifts and on-call arrangements during an incident remain governed by the labour codes in force since 21 November 2025.[8]
  • Customer contracts. Service levels, notification windows and audit rights in colocation and outsourcing agreements.

The continuity plan should assign each obligation to a role in the incident team, so that statutory reports and customer notices go out on time while engineers concentrate on recovery.

WORKING WITH LAKSHY HERE

How a Noida ISO 22301 project is served

Lakshy serves Delhi NCR, including Noida, from its New Delhi office. Lakshy ISO/GRC experts visit the facility for business impact analysis interviews, a walk-through of power, cooling, network and security dependencies with the facilities team, tabletop and live failover exercises, and the internal audit before certification. Between visits the work runs remotely on Effivity, where impact analyses, recovery plans, supplier assessments, exercise reports and improvement actions are maintained. Lakshy has not published a Noida case study; the case studies below come from ISO 22301 engagements elsewhere in India.

ISO 22301 AT A GLANCE

ISO 22301 certification: scope, steps, time and cost

ISO 22301 sets the requirements for a business continuity management system: how an organisation prepares for, responds to and recovers from disruption such as cyber incidents, fire, flood or supplier failure. A business impact analysis shows which activities matter and how fast they must resume, and a risk assessment shows what could disrupt them. Strategies, plans and an exercise programme follow. The current edition is ISO 22301:2019, with Amendment 1:2024 on climate change. An accredited certification body certifies the system after a two-stage audit. The certificate runs for three years, with annual surveillance audits.

How a Lakshy project runs. Gap assessment; business impact analysis and risk assessment; strategies, plans and procedures; exercises and internal audit; then the Stage 1 and Stage 2 audits. A typical project takes 60 to 120 days, and the exercise programme sets the pace because auditors expect evidence that plans were tested.

What it costs. Consulting and implementation support typically falls between ₹90,000 and ₹3,00,000, depending on scope and man-days, plus certification body fees of roughly ₹40,000–₹60,000 (indicative) for a small single-site organisation. Location does not change the fee structure: site visits are planned into the proposal. A free gap assessment gives an exact quotation.

Why Lakshy. ISO/GRC experts, 8,100+ clients since 2003, a 100% on-time completion record and certification only through accredited certification bodies. Work between visits runs on the free Effivity platform.

Read the full ISO 22301 guide: requirements, BIA, audit stages and costs →

Included in every Lakshy engagement: a five-user Effivity ISO & GRC software subscription and complimentary Sterling Academy awareness e-learning for your team.

FAQS

Frequently asked questions in Noida

Is an Uptime Tier certificate the same as ISO 22301?

No. A Tier certificate assesses the design or construction of a facility’s infrastructure. ISO 22301 certification covers the management system that keeps services running, including people, suppliers, plans and exercises.

Our Noida delivery centre already has a disaster recovery site. What else does ISO 22301 need?

A business impact analysis that justifies recovery objectives, plans for people and premises as well as IT, regular exercises and management review of the results.

Can a colocation tenant certify separately from the data centre?

Yes. The tenant’s system treats the data centre as a critical supplier and must assess and monitor its arrangements.

How often should exercises run?

At planned intervals set by the organisation; many data centre operators test individual systems monthly and run a full scenario exercise at least annually, with lessons tracked to closure.

Does ISO 22301 help with customer audits?

Yes. A certified system with exercise reports and management review records answers many continuity questions in colocation and outsourcing audits.

Sources for this page

  1. UP CM Yogi Adityanath inaugurates North India’s first hyperscale data centre (Invest UP, Government of Uttar Pradesh, 2022-11)
  2. Uttar Pradesh Data Center Policy 2026 (Invest UP, Government of Uttar Pradesh, 2026-07-09)
  3. List of States/UTs-wise Operational SEZs (upto 31.03.2024) (Department of Commerce, SEZ India, 2024-03-31)
  4. CAQM to take stringent action against use of heavy polluting fuels (Press Information Bureau (Ministry of Environment, Forest and Climate Change), 2022-12-28)
  5. Directions under sub-section (6) of section 70B of the Information Technology Act, 2000 (No. 20(3)/2022-CERT-In) (CERT-In, Ministry of Electronics and IT, 2022-04-28)
  6. DPDP Rules, 2025 Notified (Press Information Bureau, 2025-11-17)
  7. Online Consent Management & Monitoring System (Uttar Pradesh Pollution Control Board, accessed 2026-10-23)
  8. Welfare of Organised and Unorganised Sectors (four Labour Codes in force) (Ministry of Labour and Employment (PIB release), 2025-12-08)
TALK TO AN EXPERT

Talk to a Lakshy expert serving Noida

Lakshy ISO/GRC experts work on site with organisations across Noida. Your first conversation can be a call, a WhatsApp message or a video meeting, and we assign a dedicated ISO/GRC expert to you.

NEXT STEP

Start with a free gap assessment.

Thirty minutes with a senior specialist, benchmarking your organisation against every requirement of the standard. No cost. No obligation.

Book My Free Session
BUYER BEWAREA certificate in 7–10 days — no audit, no implementation — is not certification. It is paper.Know the red flags →
Scroll to Top